Using deep learning to generate synthetic B-mode musculoskeletal ultrasound images
Julkaisuvuosi
2020
Tekijät
Cronin, Neil J.; Finni, Taija; Seynnes, Olivier
Abstrakti:
Background and Objective Deep learning approaches are common in image processing, but often rely on supervised learning, which requires a large volume of training images, usually accompanied by hand-crafted labels. As labelled data are often not available, it would be desirable to develop methods that allow such data to be compiled automatically. In this study, we used a Generative Adversarial Network (GAN) to generate realistic B-mode musculoskeletal ultrasound images, and tested the suitability of two automated labelling approaches. Methods We used a model including two GANs each trained to transfer an image from one domain to another. The two inputs were a set of 100 longitudinal images of the gastrocnemius medialis muscle, and a set of 100 synthetic segmented masks that featured two aponeuroses and a random number of ‘fascicles’. The model output a set of synthetic ultrasound images and an automated segmentation of each real input image. This automated segmentation process was one of the two approaches we assessed. The second approach involved synthesising ultrasound images and then feeding these images into an ImageJ/Fiji-based automated algorithm, to determine whether it could detect the aponeuroses and muscle fascicles. Results Histogram distributions were similar between real and synthetic images, but synthetic images displayed less variation between samples and a narrower range. Mean entropy values were statistically similar (real: 6.97, synthetic: 7.03; p = 0.218), but the range was much narrower for synthetic images (6.91 – 7.11 versus 6.30 – 7.62). When comparing GAN-derived and manually labelled segmentations, intersection-over-union values- denoting the degree of overlap between aponeurosis labels- varied between 0.0280 – 0.612 (mean ± SD: 0.312 ± 0.159), and pennation angles were higher for the GAN-derived segmentations (25.1° vs. 19.3 °; p < 0.001). For the second segmentation approach, the algorithm generally performed equally well on synthetic and real images, yielding pennation angles within the physiological range (13.8-20°). Conclusions We used a GAN to generate realistic B-mode ultrasound images, and extracted muscle architectural parameters from these images automatically. This approach could enable generation of large labelled datasets for image segmentation tasks, and may also be useful for data sharing. Automatic generation and labelling of ultrasound images minimises user input and overcomes several limitations associated with manual analysis.
Näytä enemmänOrganisaatiot ja tekijät
Julkaisutyyppi
Julkaisumuoto
Artikkeli
Emojulkaisun tyyppi
Lehti
Artikkelin tyyppi
Alkuperäisartikkeli:
Yleisö
TieteellinenVertaisarvioitu
VertaisarvioituOKM:n julkaisutyyppiluokitus
A1 Alkuperäisartikkeli tieteellisessä aikakauslehdessäJulkaisukanavan tiedot
Lehti/Sarja
Kustantaja
Volyymi
196
Artikkelinumero
105583
ISSN
Julkaisufoorumi
Julkaisufoorumitaso
1
Avoin saatavuus
Avoin saatavuus kustantajan palvelussa
Kyllä
Julkaisukanavan avoin saatavuus
Osittain avoin julkaisukanava
Rinnakkaistallennettu
Kyllä
Avoimen saatavuuden kirjoittajamaksu €
1094
Avoimen saatavuuden kirjoittajamaksun vuosi
2020
Muut tiedot
Tieteenalat
Lääketieteen tekniikka; Liikuntatiede
Avainsanat
[object Object],[object Object],[object Object],[object Object]
Julkaisumaa
Irlanti
Kustantajan kansainvälisyys
Kansainvälinen
Kieli
englanti
Kansainvälinen yhteisjulkaisu
Kyllä
Yhteisjulkaisu yrityksen kanssa
Ei
DOI
10.1016/j.cmpb.2020.105583
Julkaisu kuuluu opetus- ja kulttuuriministeriön tiedonkeruuseen
Kyllä