Lung counting with a highly segmented HPGe detector
Julkaisuvuosi
2024
Tekijät
Jutila, Henri; Greenlees, Paul; Rahkila, Panu; Torvela, Tiina; Muikku, Maarit
Tiivistelmä
A highly segmented High-Purity Germanium (HPGe) detector was used to measure 241Am activity located inside the lungs of an anthropomorphic phantom with various active and passive shield configurations. It was found that the background suppression shield does not play a significant role in reducing the Minimum Detectable Activity (MDA) after veto, based on the segmentation in the depth direction of the HPGe, when measuring low-energy gamma rays. A reduction of up to 57% in the MDA was achieved. The MDA could be further improved by a thinner lateral segmentation and an optimized anti-Compton shield coupled with an active or passive backplate. The new detector application would be particularly useful in mobile whole-body counting units, where the natural background radiation poses a challenge when measuring low-energy gamma rays.
Näytä enemmänOrganisaatiot ja tekijät
Julkaisutyyppi
Julkaisumuoto
Artikkeli
Emojulkaisun tyyppi
Lehti
Artikkelin tyyppi
Alkuperäisartikkeli
Yleisö
TieteellinenVertaisarvioitu
VertaisarvioituOKM:n julkaisutyyppiluokitus
A1 Alkuperäisartikkeli tieteellisessä aikakauslehdessäJulkaisukanavan tiedot
Emojulkaisun nimi
Kustantaja
Volyymi
212
Artikkelinumero
111452
ISSN
Julkaisufoorumi
Julkaisufoorumitaso
1
Avoin saatavuus
Avoin saatavuus kustantajan palvelussa
Kyllä
Julkaisukanavan avoin saatavuus
Osittain avoin julkaisukanava
Rinnakkaistallennettu
Kyllä
Muut tiedot
Tieteenalat
Fysiikka; Lääketieteen tekniikka
Avainsanat
[object Object],[object Object],[object Object],[object Object],[object Object]
Julkaisumaa
Yhdistynyt kuningaskunta
Kustantajan kansainvälisyys
Kansainvälinen
Kieli
englanti
Kansainvälinen yhteisjulkaisu
Ei
Yhteisjulkaisu yrityksen kanssa
Ei
DOI
10.1016/j.apradiso.2024.111452
Julkaisu kuuluu opetus- ja kulttuuriministeriön tiedonkeruuseen
Kyllä