undefined

Feasibility and repeatability of MEG-compatible patellar-tendon stimulator for eliciting knee-joint proprioceptive cortical responses

Julkaisuvuosi

2027

Tekijät

Li, Feiyue; Byman, Anni; Chen, Junru; Mujunen, Toni; Piitulainen, Harri

Abstrakti:

Background Cortical processing of proprioceptive-dominant afference arising from the knee joint is largely unknown. Magnetoencephalography (MEG) can be used to quantify the cortical processing of the proprioceptive afference, but MEG-compatible and well-controlled stimulation of the knee joint is technically challenging, and thus has received less attention. New method We introduced a novel MEG-compatible stimulator that delivers controlled patellar tendon taps and elicits proprioceptive-dominant afferent input to the cortex in the knee joint. The stimulus intensity is adjustable, allowing graded activation of proprioceptive input and, when required, elicitation of the patellar-tendon reflex. Results The novel stimulator elicited clear muscular and cortical responses in both intensity conditions. Cortical responses demonstrated moderate to excellent intersession reliability for peak evoked field amplitude (ICC: 0.69–0.96), beta suppression (0.89–0.90) and beta rebound (0.96–0.97). Notably, beta suppression peaked more laterally than expected in both hemispheres. Peak EMG amplitudes in VL and VM muscles were reliable for both intensity conditions (ICC: 0.66–0.89), and stimulus kinematics remained consistent throughout measurements. Comparison with existing methods Previous robotic or motor-driven devices have been used to evoke cortical responses to knee-joint proprioceptive stimulation, but mechanical coupling across adjacent joints may limit knee-specific input. The present stimulator provides a mechanically simple and MEG-compatible tool that targets proprioceptive-dominant afferents of the knee joint more directly, reduces distal joint involvement. Conclusion The novel stimulator is a feasible and repeatable tool for studying cortical processing of proprioceptive afference from the knee joint using MEG.
Näytä enemmän

Organisaatiot ja tekijät

Jyväskylän yliopisto

Byman-Vornanen Anni

Li Feiyue

Piitulainen Harri Orcid -palvelun logo

Chen Junru Orcid -palvelun logo

Mujunen Toni

Helsingin yliopisto

Byman Anni

Piitulainen Harri

Helsingin yliopistollinen sairaala

Byman Anni

Piitulainen Harri

Julkaisutyyppi

Julkaisumuoto

Artikkeli

Raportti

Ei

Emojulkaisun tyyppi

Lehti

Artikkelin tyyppi

Alkuperäisartikkeli:

Yleisö

Tieteellinen

Vertaisarvioitu

Vertaisarvioitu

OKM:n julkaisutyyppiluokitus

A1 Alkuperäisartikkeli tieteellisessä aikakauslehdessä

Julkaisukanavan tiedot

Kustantaja

Elsevier

Volyymi

437

Artikkelinumero

110915

Julkaisu­foorumi

61155

Julkaisufoorumitaso

1

Avoin saatavuus

Avoin saatavuus kustantajan palvelussa

Kyllä

Julkaisukanavan avoin saatavuus

Osittain avoin julkaisukanava

Kustantajan version lisenssi

CC BY NC ND

Rinnakkaistallennettu

Kyllä

Rinnakkaistallenteen lisenssi

CC BY NC ND

Muut tiedot

Tieteenalat

Liikuntatiede; Neurotieteet

Tunnistettu aihe

[object Object]

Julkaisumaa

Alankomaat

Kustantajan kansainvälisyys

Kansainvälinen

Kieli

englanti

Kansainvälinen yhteisjulkaisu

Kyllä

Yhteisjulkaisu yrityksen kanssa

Ei

DOI

10.1016/j.jneumeth.2026.110915

Julkaisu kuuluu opetus- ja kulttuuriministeriön tiedonkeruuseen

Kyllä