undefined

Monitoring of indoor air quality at a large sailing cruise ship to assess ventilation performance and disease transmission risk

Julkaisuvuosi

2025

Tekijät

Cheung, Ho Yin Wickson; Kumar, Prashant; Hama, Sarkawt; Emygdio, Ana Paula Mendes; Wei, Yingyue; Anagnostopoulos, Lemonia; Ewer, John; Ferracci, Valerio; Galea, Edwin R.; Grandison, Angus; Hadjichristodoulou, Christos; Jia, Fuchen; Lepore, Pierfrancesco; Morawska, Lidia; Mouchtouri, Varvara A.; Siilin, Niko; Wang, Zhaozhi; HEALTHY SAILING project
Näytä enemmän

Tiivistelmä

<p>Large passenger ships are characterised as enclosed and crowded indoor spaces with frequent interactions between travellers, providing conditions that facilitate disease transmission. This study aims to provide an indoor ship CO<sub>2</sub> dataset for inferring thermal comfort, ventilation and infectious disease transmission risk evaluation. Indoor air quality (IAQ) monitoring was conducted in nine environments (three cabins, buffet, gym, bar, restaurant, pub and theatre), on board a cruise ship voyaging across the UK and EU, with the study conducted in the framework of the EU HEALTHY SAILING project. CO<sub>2</sub> concentrations, temperature and relative humidity (RH) were simultaneously monitored to investigate thermal characteristics and effectiveness of ventilation performance. Results show a slightly higher RH of 68.2 ± 5.3 % aboard compared to ASHRAE and ISO recommended targets, with temperature recorded at 22.3 ± 1.4 °C. Generally, good IAQ (&lt;1000 ppm) was measured with CO<sub>2</sub> mainly varying between 400 and 1200 ppm. The estimated air change rates (ACH) and ventilation rates (VR) implied sufficient ventilation was provided in most locations, and the theatre (VR: 86 L s<sup>−1</sup> person<sup>−1</sup>) and cabins (VR: &gt;20 L s<sup>−1</sup> person<sup>−1</sup>) were highly over-ventilated. Dining areas including the pub and restaurant recorded high CO<sub>2</sub> concentrations (&gt;2000 ppm) potentially due to higher footfall (0.6 person m<sup>−2</sup> and 0.4 person m<sup>−2</sup>) and limited ACH (2.3 h<sup>−1</sup> and 0.8 h<sup>−1</sup>), indicating a potential risk of infection; these areas should be prioritised for improvement. The IAQ and probability of infection indicate there is an opportunity for energy saving by lowering hotel load for the theatre and cabins and achieving the minimum acceptable VR (10 L s<sup>−1</sup> person<sup>−1</sup>) for occupants' comfort and disease control. Our study produced a first-time dataset from a sailing cruise ship's ventilated areas and provided evidence that can inform guidelines about the optimisation of ventilation operations in large passenger ships, contributing to respiratory health, infection control and energy efficiency aboard.</p>
Näytä enemmän

Organisaatiot ja tekijät

Julkaisutyyppi

Julkaisumuoto

Artikkeli

Emojulkaisun tyyppi

Lehti

Artikkelin tyyppi

Alkuperäisartikkeli

Yleisö

Tieteellinen

Vertaisarvioitu

Vertaisarvioitu

OKM:n julkaisutyyppiluokitus

A1 Alkuperäisartikkeli tieteellisessä aikakauslehdessä

Julkaisukanavan tiedot

Volyymi

962

Artikkelinumero

178286

Julkaisu­foorumi

66887

Julkaisufoorumitaso

2

Avoin saatavuus

Avoin saatavuus kustantajan palvelussa

Kyllä

Julkaisukanavan avoin saatavuus

Osittain avoin julkaisukanava

Kustantajan version lisenssi

CC BY

Rinnakkaistallennettu

Ei

Muut tiedot

Tieteenalat

Ympäristötekniikka

Avainsanat

[object Object],[object Object],[object Object],[object Object],[object Object],[object Object],[object Object],[object Object]

Kieli

englanti

Kansainvälinen yhteisjulkaisu

Kyllä

Yhteisjulkaisu yrityksen kanssa

Kyllä

DOI

10.1016/j.scitotenv.2024.178286

Julkaisu kuuluu opetus- ja kulttuuriministeriön tiedonkeruuseen

Kyllä